Generator Cycle Electric 12 V sort FL/FX 65-81
12 V generator i OEM-stil fra Cycle Electric
Læs mere
- Højkvalitets konstruktion og komponenter
- Balanceviklet anker med epoxybundne tråde smeltet sammen med kommutatoren
- Viklinger sikret med trådkiler af ahorn
- Sort finish
- 12 V generator dimensioneret til 10 ampere
- Tandhjul kan genbruges
- Fremstillet i USA
Passer også til konvertering til 12 V på H-D 36-84. Ved udskiftning af 65B-generator (82-84 Hitachi) skal olieafviser #31035-58 (MCS 555773) monteres. Regulatoren skal begrænse strømudtaget til 10 ampere for ikke at brænde generatoren af – kontrollér regulatoren ved montering.
Passer til: Sportster 77-84
OEM-nr.: 29975-65A, 29975-65B, 31035-58
| Kategori | Generators |
| Produkt-typ | Generators |
American-Made Generator
- High-quality construction and components; manufactured by the same company that supplies OEM
- Armature is balance wound, and the epoxy-bonded wires are fused to the commutator; hard maple wire wedges secure the windings
- Made in the USA
- 12-Volt generator. Black
- OEM style reproduction for stock style restaurations
- OEM replacement for 29975-65B
- Will also fit 36-84 H-D when converting to 12 Volt
- Note: When replacing 65B generator (82-84 Hitachi), add H-D #31035-58 (MCS 555773) oil deflector
- Same gear can be re-used
- Tech tip generator polarizing: With the motor off connect the 'F' terminal to ground and momentarily flash the 'A' terminal with positive
- If you have properly installed a working regulator it will turn on and ground the 'F' terminal in which case you will not need to use an external ground
- Caution!
- This will damage the regulator
- Do not connect the battery to the Field (F terminal) as this will polarize the generator backwards
- Generators in general don't forget their polarization so it is not necessary to polarize a generator from Cycle Electric Inc. unless it was connected to a battery backwards or inadvertently polarized backwards after it left the factory
- Only after a long time period generators can struggle to come up and polarization can be a good idea
- Tech tip maximum generator amperage: The model -65A 12 volt generator is rated at 10 amps
- It is capable of producing 25 to 30 amps
- If you draw 20 amps. out of a 10 amp. generator it will burn-up within 20 minutes
- It is the regulator's job to limit the amps. that are drawn from the generator to 10 amps
- We recommend testing your regulator when installing a new generator
- Also, some regulators do not regulate amps
- These should not be used
- All Cycle Electric regulators will insure correct amperage regulation
Fits: 65-69 Big Twin; 65-81 XL Sportster (NU)